Independent OT security assurance

We verify the security of critical control systems.

OTSENTINEL assesses, reviews and verifies OT security for asset owners, EPC contractors and system integrators across the Middle East and India: power, water, renewables, oil & gas and other critical infrastructure, against IEC 62443 and the national rules where you operate.

Example zones and conduits across reference levelsExample of control-system zones from enterprise IT down to field devices, using Purdue / ISA-95 reference levels, connected by conduits. Each zone and conduit has an example target security level; real values come from a risk assessment under IEC 62443-3-2.L4ENTERPRISEEnterprise ITERP · email · business systemsSL-T 1SL-T 2L3.5IDMZIndustrial DMZhistorian replica · patch server · remote accessSL-T 2SL-T 3L3OPERATIONSCONTROL CTRSite operationshistorian · eng. workstationsSL-T 2EMScontrol centreSL-T 3SL-T 3SL-T 3L2SUPERVISORYSCADA / HMIoperator stationsSL-T 3DCScontrol serversSL-T 3SL-T 3SL-T 3L1CONTROLPLC · RTUcontrollersSL-T 3IED · relaysprotectionSL-T 3L0PROCESSSensors · breakers · pumps · drives
EXAMPLE ZONES & CONDUITS · REFERENCE LEVELS: PURDUE / ISA-95 · SL-T (TARGET SECURITY LEVEL) SET PER ZONE AND CONDUIT BY RISK ASSESSMENT, IEC 62443-3-2 · VALUES ILLUSTRATIVE
For EPCs, contractors and system integrators

Won a project with an OT security scope? We become your OT security team.

Many contractors and integrators across the Middle East and India win projects where the owner requires OT cybersecurity, but have no OT security specialists in-house. Buying a monitoring product rarely covers the whole requirement. The owner still expects cybersecurity documents, tests and compliance at every stage. We deliver that part for you, stage by stage.

Talk to an engineer →
Project stageWhat the owner asks forHow OTSENTINEL helps
BidCybersecurity section of the technical offer, compliance statementTender cybersecurity section, compliance matrix against the specification
DesignSecurity philosophy, zone and conduit design, risk assessment, remote access designOT security engineering documents, risk register, remote access design review
FAT / SATCybersecurity test procedures, firewall validation, hardening evidence, witnessed testsTest procedures, hardening checklists, witnessing and test reports
Handover (TOC / FAC)Verified asset inventory, backups, policies, final cybersecurity acceptanceAsset inventory check, backup readiness audit, policies and procedures, final compliance statement
ComplianceOwner requirements and national rules (Qatar ICS standard, Saudi OTCC, UAE, Oman, Kuwait, India CEA and others)Gap assessment and national standards compliance review

Asset owners use the same services with us as their independent OT security inspector at FAT, SAT, TOC and FAC. On any one project we work for one side only.

Where do you need help?

We won a project with an OT security scope

Your owner expects cybersecurity documents, tests and compliance. We work as your OT security team from bid to final acceptance.

See how we help →

We need an OT cybersecurity audit

A structured assessment against IEC 62443 and your national rules: Qatar, Saudi Arabia, UAE, Oman, Kuwait, Bahrain, India's CEA regulations and more.

See how we help →

We need an OT security inspector for FAT, SAT, TOC or FAC

Independent cybersecurity inspection and witnessing at each project milestone, so it is accepted on evidence.

See how we help →

We want our substations reviewed

Security review of substation control systems, their link to the control centre and every external connection.

See how we help →

We don't know who can access our systems remotely

A review of every remote and vendor access path, the controls in place and the logs, plus a clear remote access policy.

See how we help →

We don't have a reliable OT asset inventory

Set up from scratch, cleaned up after a monitoring tool is installed, or checked at project handover.

See how we help →

We need a proper OT risk register

Set up from scratch or streamlined: risks linked to real assets and consequences, with owners and actions.

See how we help →

Are our backups really ready?

An audit of OT backups, schedules and restore evidence: one-off, at handover or every six months.

See how we help →

We need OT security policies and procedures

Remote access, change management, backup, incident response and more: written for the plant and ready for audit.

See how we help →
Our services

Our services, one standard of evidence

All services →
Per stage or full lifecycle

Project Lifecycle Cybersecurity Support & Inspections

OT security support and inspection at every project stage: scope of work, bid, design, FAT, SAT, TOC and FAC.

Details →
Per project stage, or a monthly fee on longer projects

Integrator & EPC Compliance Support for Project Delivery

We work on your side to deliver a project that meets IEC 62443, the owner's specification and national standards.

Details →
3–5 weeks per site, depending on scope

OT Cybersecurity Audit, Gap Assessment & National Standards Compliance

Assess your control systems against IEC 62443 and the national critical-infrastructure rules of each country where you operate.

Details →
Per substation design, test event or in-service substation; lower price for repeat designs

Substation Control System Security Review

Security review of substation control systems, their link to the control centre and every external and remote connection.

Details →
Review, policy pack, or both; optional yearly check

Remote Access Security Review & Policy

Find every remote and vendor access path, check the security in place and set a clear remote access policy.

Details →
Fixed price per package: set-up, clean-up and prioritisation, or project asset check

OT Asset Inventory Services

Set up your OT asset inventory, clean it up after a monitoring tool is installed, or check it at project handover.

Details →
Fixed-scope project, optional periodic review support

OT Risk Register Set-up & Streamlining

We set up a working OT cybersecurity risk register, or fix one that isn't managed properly, and hand it over to your team.

Details →
3–4 weeks per unit or system, depending on scope

OT Security Engineering Documents

IEC 62443 project documentation: security philosophy, zone and conduit design, risk assessment and compliance matrices.

Details →
2–6 weeks for a full set; single policies from a few days

OT Security Policies & Procedures

Practical OT cybersecurity policies and procedures your engineers can follow and your auditors will accept.

Details →
One-off audit, handover check, or every six months on a yearly contract

OT Backup & Restore Readiness Audit

Verify that your control systems have proper, scheduled and complete backups, and that restore is ready.

Details →
Day rate under a framework agreement, or fixed price per work package

OT Specialist Support for Consulting & Audit Firms

An experienced OT security specialist for your audit and assessment teams.

Details →
Monthly fee for set days per month, 6 to 12 month contract

Resident & Part-time OT Security Lead

An experienced OT security lead for a set number of days per month, or for a fixed period.

Details →
From a few days to an ongoing retainer

OT Cybersecurity Review & Advisory

Targeted reviews, supplier assessments, incident response plans and exercises for OT teams.

Details →
Project lifecycle assurance

Cybersecurity assurance at every project stage

Most cybersecurity problems on projects are cheapest to fix early. We review each milestone against the specification and standards, for the owner or for the contractor, so nothing reaches handover unchecked.

How it works →
  1. FEEDConcept / FEED
  2. SOWScope of work & specification
  3. BIDBidder offer evaluation
  4. DESDetailed design
  5. FATFactory acceptance test
  6. SATSite acceptance & commissioning
  7. TOCTake-over certificate
  8. FACFinal acceptance certificate

Why independent assurance

No product to sell

We don't resell hardware, software or licences. Our recommendations follow the risk, not a catalogue.

A second pair of eyes

A control-system vendor can't credibly verify its own design. We give owners and EPCs an independent view they can rely on.

Engineering first

Plant safety and availability come before everything. We assess, review, document and witness. We never make hands-on changes to live systems: your team or your vendor does that.

Sectors

Critical infrastructure we work in

Our methods apply wherever industrial control systems run essential services. We lead with power, water and renewables, where our experience is deepest, and work in other sectors with specialist partners.

All sectors →

Where we work: the Middle East and India

QatarUnited Arab EmiratesSaudi ArabiaOmanKuwaitBahrainOther Middle East countriesIndia
Standards

Assessed against the rules that apply to you

Standards & compliance →
IEC 62443IEC 62351ISO/IEC 27001 · 27019IEC 61511 interfaceNIST SP 800-82 Rev. 3NIST CSF 2.0NIST SP 800-53 Rev. 5NIST IR 8183CEA Regulations 2026CEA GuidelinesCERT-In DirectionsNCIIPCDPDP Act 2023Qatar National ICS Security StandardNIASPDPPLUAE IA RegulationDubai ISRUAE PDPLNCA ECCNCA OTCCNCA CSCCAramco SACS-002 · CCCSaudi PDPLOmanKuwaitBahrainNIS Regulations 2018NCSC CAFUK GDPR

How an engagement runs

  1. Scope

    Agree the systems, standards, deliverables, acceptance criteria and how your data is handled.

  2. Collect

    Gather drawings, architecture, configurations and interviews through an agreed, secure channel.

  3. Assess

    Evaluate against IEC 62443 and the applicable national rules. Every finding is tied to evidence and a clause.

  4. Report

    A findings register, risk ratings and a prioritised remediation roadmap, reviewed with your team.

  5. Support

    Clarifications, re-checks of fixes and support through acceptance, FAT and SAT.

Learn

New to OT security?

Short, practical guides for managers and engineers: why control systems need different protection, and what every operator of critical infrastructure should have in place.

All guides →
Trust

Your data stays protected

We sign an NDA before any data changes hands, use encrypted channels you approve, never put client data into public AI tools, and return or delete everything at the end of the engagement.

How we protect your data

Have a project or an audit coming up?

Tell us what you're working on. An engineer will reply, usually within two working days.